CONNECTION OF SENSOR FSD-90030:
Press the ON / SET button on the main control panel. The right lamp lights up green. Hold down the ON / SET button on the main control panel until the left lamp lights up red. Release the button. Click once on the SET button on the sensor. Sensor will flash red and give two beeps confirming that it is connected. Repeat when connecting several sensors
RESET OF THE SYSTEM AFTER TESTING:
Press the SET button on the sensor once, then press the main unit ON / SET once.
RESET MAIN CENTER:
Hold down the OFF / DEL button on the main control panel until it beeps, hold down the button until it stops beeping. All sensors are now switched off.

.

.

.

.

.

Installation of sensor cables: IMPORTANT!!
Sensor cables must not be glued directly to metal inside the distribution cabinet. There will be creeping current and FlowStop will shut down. Sensor cable is glued on top of other tape / piece of wood etc. Sensor cable cannot be folded or lost in metal, FlowStop will strike. Sensor cable is glued down and cut to the desired length.

.

.

CONNECTION OF PUCK FSD-90031
Unscrew the lid. Insert battery Press ON / SET button on main control panel. The right lamp lights up green. Hold down the ON / SET button on the main control panel until the left lamp lights up red. Release the button. Click once on the BLACK button on the puck. Sensor will flash red and give two beeps confirming that it is connected. Screw on the lid. . Repeat when connecting several sensors
PUCK INSTALLATION:
Place in a suitable place, making sure that the puck is not near metal.
RESET OF THE SYSTEM AFTER TESTING:
Press the BLACK button puck once, then press the main unit ON / SET once.
RESET MAIN CENTER:
Hold down the OFF / DEL button on the main control panel until it beeps, hold down the button until it stops beeping. All sensors are now switched off

Battery: If the battery level is low, a sound will be issued approximately every 30 seconds. By pressing SET, the sound will stop but will return after about 30 seconds. This will result in the main control center also notifying with a sound and closing the valve. CHANGE BATTERY type CR2 3Volt. Can be bought at Clas Ohlson, Jula, Biltema etc.

lagt til handlevogn